Availability: | |
---|---|
Quantity: | |
Features:
•Simple and intelligentized operation
Front door can be opened, you can stop it at any moment which is very convenient for reagent optimization and experimental status viewing
Start with self-check, equipped with power-off protection
8-plate identification design guaranteed their target position, even though external forces exist
Automatic detection in case kit missing
•Antipollution measures
Avoid reagent splashing through drip shield plate and beads dried way controlled by software
Disposable consumables which can avoid cross contamination
•Reliable structure and stable operation
Adopt lead screw drive to realize high-precision lifting movement
Patent structure design with center rotary table which makes it occupies smaller area
Patent design for automatic loading and unloading structure of magnetic rod comb, which guaranteed stability and liability (success rate >99.99 %)
•High quality and fast extraction
Auto-Pure 96 can process 96x1 ml samples simultaneously
Auto-Pure 48 can process 48x3 ml samples simultaneously
Auto-Pure 24 can process 24x10 ml samples simultaneously
Effectively avoid the influence of human factors on the experiment
•Open design, free program editing
Accurate temperature control at RT+5 ℃-120 ℃
Single machine can realize program editing
The software has complete functions and is suitable for all kinds of magnetic bead method reagents.
Diversified mixing and magnetic attraction methods are beneficial to reagent optimization
Technical parameter:
Model | Auto-Pure 96/Auto-Pure 48/Auto-Pure 24 |
Throughpu | 1~96(Auto-Pure 96);1~48 (Auto-Pure 48);1~24 (Auto-Pure 24) |
Process volume | 50~1000 μL(Auto-Pure 96);50~3000 μL(1~48);50~10000 μL(Auto-Pure 24) |
Consumable | 96 deep well plate +96 magnetic rod comb (Auto-Pure 96);3 mL kit +magnetic rod comb (Auto-Pure 48);10 mL kit + |
magnetic rod comb (Auto-Pure 24) | |
Principle/working mode | Magnetic bead method,magnetic rod type/circular rotary table type |
Purification accuracy | 100 copy sample positive rate>95 % |
Stability | CV<5 % |
Collectjon efficiency | >95 % |
Heating for lysis tube | Ambient temperature~120 ℃ |
Heating for elution tube | Ambient temperature~120 ℃ |
Operation | 7-inch touch screen,3 shortcut keys,extenal mouse |
Internal program | Preset 8 programs,max store 100 programs |
Protocol management | Create,edit,delete,protocol mode |
Fxtension interface | 4 standard USB port,Ethernet port,wifi,built-in SD card |
Lighting | Yes |
Pollution control | UV sterilization |
Exhaust | Fan |
Power supply | 300 W |
Dimension | 560×620×500 mm |
Weight | 54 kg |
Features:
•Simple and intelligentized operation
Front door can be opened, you can stop it at any moment which is very convenient for reagent optimization and experimental status viewing
Start with self-check, equipped with power-off protection
8-plate identification design guaranteed their target position, even though external forces exist
Automatic detection in case kit missing
•Antipollution measures
Avoid reagent splashing through drip shield plate and beads dried way controlled by software
Disposable consumables which can avoid cross contamination
•Reliable structure and stable operation
Adopt lead screw drive to realize high-precision lifting movement
Patent structure design with center rotary table which makes it occupies smaller area
Patent design for automatic loading and unloading structure of magnetic rod comb, which guaranteed stability and liability (success rate >99.99 %)
•High quality and fast extraction
Auto-Pure 96 can process 96x1 ml samples simultaneously
Auto-Pure 48 can process 48x3 ml samples simultaneously
Auto-Pure 24 can process 24x10 ml samples simultaneously
Effectively avoid the influence of human factors on the experiment
•Open design, free program editing
Accurate temperature control at RT+5 ℃-120 ℃
Single machine can realize program editing
The software has complete functions and is suitable for all kinds of magnetic bead method reagents.
Diversified mixing and magnetic attraction methods are beneficial to reagent optimization
Technical parameter:
Model | Auto-Pure 96/Auto-Pure 48/Auto-Pure 24 |
Throughpu | 1~96(Auto-Pure 96);1~48 (Auto-Pure 48);1~24 (Auto-Pure 24) |
Process volume | 50~1000 μL(Auto-Pure 96);50~3000 μL(1~48);50~10000 μL(Auto-Pure 24) |
Consumable | 96 deep well plate +96 magnetic rod comb (Auto-Pure 96);3 mL kit +magnetic rod comb (Auto-Pure 48);10 mL kit + |
magnetic rod comb (Auto-Pure 24) | |
Principle/working mode | Magnetic bead method,magnetic rod type/circular rotary table type |
Purification accuracy | 100 copy sample positive rate>95 % |
Stability | CV<5 % |
Collectjon efficiency | >95 % |
Heating for lysis tube | Ambient temperature~120 ℃ |
Heating for elution tube | Ambient temperature~120 ℃ |
Operation | 7-inch touch screen,3 shortcut keys,extenal mouse |
Internal program | Preset 8 programs,max store 100 programs |
Protocol management | Create,edit,delete,protocol mode |
Fxtension interface | 4 standard USB port,Ethernet port,wifi,built-in SD card |
Lighting | Yes |
Pollution control | UV sterilization |
Exhaust | Fan |
Power supply | 300 W |
Dimension | 560×620×500 mm |
Weight | 54 kg |