Availability: | |
---|---|
Quantity: | |
Features:
•Stand-alone operation, 7-inch color touch screen display, easy to use
•Customize the temperature and program according to the requirements
•Short operation time, 15-30 min/time, can extract up to 32 samples in one run
•High yield of nucleic acid, low loss of magnetic beads, and good reproducibility of results
•UV sterilization function to avoid cross-contamination
•Open system, suitable for various magnetic bead extraction reagents
•Drawer design to prevent possible injuries
•APP software will be configured to monitor the system in real time through mobile devices
Technical parameter:
Model | Auto-Pure32A |
Throughput | 1~32 |
Process volume | 50~1000 μl |
Consumable | 96 Deepwell plate+magnetic rod comb |
Principle/working mode | Magnetic bead method,magnetic rod method /up and down mixing |
Software security design | Operating system encryption function can effectively prevent malicious tampering of parameters and programs |
Anti-pollution design | 6 fan convection design,effectively prevent aerosol pollution |
Purification accuracy | 100 copy sample positive rate>95% |
Stability | CV<5% |
Collection efficiency | >95% |
Heating for lysis tube | Ambient temperature~120 ℃ |
Heating for elution tube | Ambient temperature~120 ℃ |
Operation | 7-inch touch screen,3 shortcut keys,external mouse |
Internal program | Preset 8 programs,max store 100 programs |
Protocol management | Create,edit,delete,protocol mode |
Extension interface | 4 standard USB port,Ethernet port,wifi,built-in SD card |
Lighting | Yes |
Pollution control | UV light |
Exhaust | Fan |
Power supply | 450 W |
Dimension | 400×470×450 mm |
Weight | 28 kg |
Features:
•Stand-alone operation, 7-inch color touch screen display, easy to use
•Customize the temperature and program according to the requirements
•Short operation time, 15-30 min/time, can extract up to 32 samples in one run
•High yield of nucleic acid, low loss of magnetic beads, and good reproducibility of results
•UV sterilization function to avoid cross-contamination
•Open system, suitable for various magnetic bead extraction reagents
•Drawer design to prevent possible injuries
•APP software will be configured to monitor the system in real time through mobile devices
Technical parameter:
Model | Auto-Pure32A |
Throughput | 1~32 |
Process volume | 50~1000 μl |
Consumable | 96 Deepwell plate+magnetic rod comb |
Principle/working mode | Magnetic bead method,magnetic rod method /up and down mixing |
Software security design | Operating system encryption function can effectively prevent malicious tampering of parameters and programs |
Anti-pollution design | 6 fan convection design,effectively prevent aerosol pollution |
Purification accuracy | 100 copy sample positive rate>95% |
Stability | CV<5% |
Collection efficiency | >95% |
Heating for lysis tube | Ambient temperature~120 ℃ |
Heating for elution tube | Ambient temperature~120 ℃ |
Operation | 7-inch touch screen,3 shortcut keys,external mouse |
Internal program | Preset 8 programs,max store 100 programs |
Protocol management | Create,edit,delete,protocol mode |
Extension interface | 4 standard USB port,Ethernet port,wifi,built-in SD card |
Lighting | Yes |
Pollution control | UV light |
Exhaust | Fan |
Power supply | 450 W |
Dimension | 400×470×450 mm |
Weight | 28 kg |