Features:
Large volume extraction to meet special needs
l The maximum reaction system of the sample library is 5 / 10 mL, which can meet the needs of cfDNA extraction
l The elution well is eluted in a small volume to meet the nucleic acid concentration requirements
High-precision liquid handling
l Dual-channel pipetting design, 1×(50 - 5000 μL),suitable for 1 mL /
5 mL pipettor and 1×(1 - 200 μL),suitable for 200 μL pipettor
l The pipettor’s pressure detection technology can not only detect the height of the liquid level, but also empty suction, residual liquid volume and blockage detection
l Detailed pipetting parameter settings for different liquids can effec- tively improve the accuracy
Methylation transfer special functional modules
l Module temperature control range 4 °C ~ 105 °C
l In order to meet the methylation requirements, 2400M adds a temperature control module to realize multi-stage temperature change
l Thermo lid design can prevent reagent condensation from affecting the reagent concentration in the tube, and has the technology to prevent cross-contamination
Easy-to-learn operating software
l Graphical user interface, program editing can be completed without complicated operations
l Built-in comprehensive libraries of consumable arriers and liquids to reduce customer program matching time
l Users can simply select according to their needs to complete the whole process of liquid handling, extraction, and PCR / qPCR setup
Specifications:
Model | Auto-Pure 2400 | Auto-Pure 2400M | Auto-Pure 4800 | |
Function | Automatic pipette samples / reagents, extract nucleic acid and setup PCR systems | Automatic pipette samples, extract nucleic acid and setup PCR systems | ||
Information management | Support external USB scanner, barcode scanning function, automatic scanning function | |||
Pipetting principle | Air displacement pipetting technology | |||
Pipettor | One 5000 μL pipettor and one 200 μL pipettor | Two 1000 μL pipettors and one 200 μL pipettor | ||
Pipetting range (μL) | 1 - 5000 μL | 1 - 1000 μL | ||
Tips | Allsheng tips, and other tips compatible with this instrument | |||
Liquid detection | Pressure detection: liquid level detection, tip clogging detection and residual liquid detection | |||
Samples per run | 1 - 24 | 1 - 48 | ||
Process volume | 50 - 10000 μL | 50 - 1000 μL | ||
Extraction uniformity | CV ≤ 5 % | |||
Single sample consumables | Support | |||
Heating temperature | Elution and lysis temperature control: RT. ~ 120 °C | |||
Cooling module | -- | 0 °C ~ 105 °C (optional) | ||
Temperature control module | -- | 4 °C ~ 105 °C | -- | |
UV sterilization | Separate UV lamp: extraction area, pipetting area and waste container area | |||
Fan filter | Equipped with three HEPA filters | |||
Instrument port | USB port | |||
Power supply | 220 V, 8 A, 50 / 60 Hz | |||
Power | Standby 30 W, maximum 600 W | Standby 30 W, maximum 550 W | ||
Noise | ≤ 60 dB | |||
Net weight | 130 kg |
Features:
Large volume extraction to meet special needs
l The maximum reaction system of the sample library is 5 / 10 mL, which can meet the needs of cfDNA extraction
l The elution well is eluted in a small volume to meet the nucleic acid concentration requirements
High-precision liquid handling
l Dual-channel pipetting design, 1×(50 - 5000 μL),suitable for 1 mL /
5 mL pipettor and 1×(1 - 200 μL),suitable for 200 μL pipettor
l The pipettor’s pressure detection technology can not only detect the height of the liquid level, but also empty suction, residual liquid volume and blockage detection
l Detailed pipetting parameter settings for different liquids can effec- tively improve the accuracy
Methylation transfer special functional modules
l Module temperature control range 4 °C ~ 105 °C
l In order to meet the methylation requirements, 2400M adds a temperature control module to realize multi-stage temperature change
l Thermo lid design can prevent reagent condensation from affecting the reagent concentration in the tube, and has the technology to prevent cross-contamination
Easy-to-learn operating software
l Graphical user interface, program editing can be completed without complicated operations
l Built-in comprehensive libraries of consumable arriers and liquids to reduce customer program matching time
l Users can simply select according to their needs to complete the whole process of liquid handling, extraction, and PCR / qPCR setup
Specifications:
Model | Auto-Pure 2400 | Auto-Pure 2400M | Auto-Pure 4800 | |
Function | Automatic pipette samples / reagents, extract nucleic acid and setup PCR systems | Automatic pipette samples, extract nucleic acid and setup PCR systems | ||
Information management | Support external USB scanner, barcode scanning function, automatic scanning function | |||
Pipetting principle | Air displacement pipetting technology | |||
Pipettor | One 5000 μL pipettor and one 200 μL pipettor | Two 1000 μL pipettors and one 200 μL pipettor | ||
Pipetting range (μL) | 1 - 5000 μL | 1 - 1000 μL | ||
Tips | Allsheng tips, and other tips compatible with this instrument | |||
Liquid detection | Pressure detection: liquid level detection, tip clogging detection and residual liquid detection | |||
Samples per run | 1 - 24 | 1 - 48 | ||
Process volume | 50 - 10000 μL | 50 - 1000 μL | ||
Extraction uniformity | CV ≤ 5 % | |||
Single sample consumables | Support | |||
Heating temperature | Elution and lysis temperature control: RT. ~ 120 °C | |||
Cooling module | -- | 0 °C ~ 105 °C (optional) | ||
Temperature control module | -- | 4 °C ~ 105 °C | -- | |
UV sterilization | Separate UV lamp: extraction area, pipetting area and waste container area | |||
Fan filter | Equipped with three HEPA filters | |||
Instrument port | USB port | |||
Power supply | 220 V, 8 A, 50 / 60 Hz | |||
Power | Standby 30 W, maximum 600 W | Standby 30 W, maximum 550 W | ||
Noise | ≤ 60 dB | |||
Net weight | 130 kg |