Availability: | |
---|---|
Quantity: | |
Features:
•Stand-alone operation, 7-inch color touch screen display, easy to use
•Customize the temperature and program according to the requirements
•Short operation time, 15-30 min/time, can extract up to 20 samples in one run
•High yield of nucleic acid, low loss of magnetic beads, and good reproducibility of results
•UV sterilization function to avoid cross-contamination
•Open system, suitable for various magnetic bead extraction reagents
•Drawer design to prevent possible injuries
•APP software will be configured to monitor the system in real time through mobile devices
Technical parameter:
Model | Auto-Pure 20A |
Throughpu | 1~20 |
Process yolume | 50~3000μ |
Collection efficiency | >95 % |
Magnetic rod number | 20 |
Purification accuracy | 100 copy sample positive rate>95 % |
Stability | CV<5% |
Consumable | 2 ml cartridge +magnetic rod comb |
Heating for lysis tube | Ambient temperature~120 ℃ |
Heating for elution tube | Ambient temperature~120 ℃ |
Operation | 7-inch touch screen,3 shortcut keys,external mouse |
Storage capacity | Preset 8 programs,max store 100 programs |
Protocol management | Create,edit,delete,protocol mode |
Extension interface | 4 standard USB port,Ethernet port,wifi,built-in SD card |
Lighting | Yes |
Pollution contro | UV light |
Fxhaust | Fan |
Power supply | 450 W |
Dimension | 400×520×450 mm |
Weight | 30 kg |
Features:
•Stand-alone operation, 7-inch color touch screen display, easy to use
•Customize the temperature and program according to the requirements
•Short operation time, 15-30 min/time, can extract up to 20 samples in one run
•High yield of nucleic acid, low loss of magnetic beads, and good reproducibility of results
•UV sterilization function to avoid cross-contamination
•Open system, suitable for various magnetic bead extraction reagents
•Drawer design to prevent possible injuries
•APP software will be configured to monitor the system in real time through mobile devices
Technical parameter:
Model | Auto-Pure 20A |
Throughpu | 1~20 |
Process yolume | 50~3000μ |
Collection efficiency | >95 % |
Magnetic rod number | 20 |
Purification accuracy | 100 copy sample positive rate>95 % |
Stability | CV<5% |
Consumable | 2 ml cartridge +magnetic rod comb |
Heating for lysis tube | Ambient temperature~120 ℃ |
Heating for elution tube | Ambient temperature~120 ℃ |
Operation | 7-inch touch screen,3 shortcut keys,external mouse |
Storage capacity | Preset 8 programs,max store 100 programs |
Protocol management | Create,edit,delete,protocol mode |
Extension interface | 4 standard USB port,Ethernet port,wifi,built-in SD card |
Lighting | Yes |
Pollution contro | UV light |
Fxhaust | Fan |
Power supply | 450 W |
Dimension | 400×520×450 mm |
Weight | 30 kg |