Availability: | |
---|---|
Quantity: | |
Features:
· 32-bit high-speed low-power MCU
· Four channels
· K, T and J type thermocouple supported
· Resolution up to 0.01℃
· Factory accuracy ±(0.3%|t|+0.40)℃
· Accuracy up to ±0.1℃ after point calibration
· Measuring range -200℃~+1370℃
Specifications:
Model | YET-640 | YET-640L | YET-640X |
Channel | 4 | ||
Recording Function | No | Yes | |
PC Software | No | No | Yes |
Probe Type | K, T, J type thermocouple | ||
Unit | ℃, ℉ | ||
Measuring Range | K Type: -200℃~+1370℃ T Type: -200℃~+400℃ J Type: -200℃~+1200℃ | ||
Resolution | 0.01℃(-200.00℃~+999.99℃) 0.1℃(+1000.0℃~+1370.0℃) | ||
Accuracy | ±(0.3%|t|+0.40)℃ | ||
Sample Rate | 2 times/second | ||
Calibration | Multi-point calibration | ||
Storage Capacity | No | 20000 groups of readings | |
Sample Interval | No | 1~86399 seconds adjustable | |
File Format | No | txt, csv, xls | Up to PC software |
Compatible System | No | Windows XP/Vista/7/8/10 | |
Display | Dot matrix LCD display with backlight | ||
Operation Temperature | -10℃~+50℃(Non-condensing) | ||
Storage Temperature | -20℃~+60℃(Without battery) | ||
Power Supply | 3 pcs of 1.5V AAA alkaline batteries 3 pcs of 1.2V AAA rechargeable batteries 5V USB (not recommended) | ||
Battery Life | About 100 hours (Condition: Instrument continues to work, backlight is off, battery capacity is 1200mAh and environment temperature is 25℃) | ||
Protection Class | IP52 | ||
Dimension | 176*73*40mm | ||
Weight | About 216g (Not including batteries and probes) |
Features:
· 32-bit high-speed low-power MCU
· Four channels
· K, T and J type thermocouple supported
· Resolution up to 0.01℃
· Factory accuracy ±(0.3%|t|+0.40)℃
· Accuracy up to ±0.1℃ after point calibration
· Measuring range -200℃~+1370℃
Specifications:
Model | YET-640 | YET-640L | YET-640X |
Channel | 4 | ||
Recording Function | No | Yes | |
PC Software | No | No | Yes |
Probe Type | K, T, J type thermocouple | ||
Unit | ℃, ℉ | ||
Measuring Range | K Type: -200℃~+1370℃ T Type: -200℃~+400℃ J Type: -200℃~+1200℃ | ||
Resolution | 0.01℃(-200.00℃~+999.99℃) 0.1℃(+1000.0℃~+1370.0℃) | ||
Accuracy | ±(0.3%|t|+0.40)℃ | ||
Sample Rate | 2 times/second | ||
Calibration | Multi-point calibration | ||
Storage Capacity | No | 20000 groups of readings | |
Sample Interval | No | 1~86399 seconds adjustable | |
File Format | No | txt, csv, xls | Up to PC software |
Compatible System | No | Windows XP/Vista/7/8/10 | |
Display | Dot matrix LCD display with backlight | ||
Operation Temperature | -10℃~+50℃(Non-condensing) | ||
Storage Temperature | -20℃~+60℃(Without battery) | ||
Power Supply | 3 pcs of 1.5V AAA alkaline batteries 3 pcs of 1.2V AAA rechargeable batteries 5V USB (not recommended) | ||
Battery Life | About 100 hours (Condition: Instrument continues to work, backlight is off, battery capacity is 1200mAh and environment temperature is 25℃) | ||
Protection Class | IP52 | ||
Dimension | 176*73*40mm | ||
Weight | About 216g (Not including batteries and probes) |