Availability: | |
---|---|
Quantity: | |
Features:
· 32-bit high-speed low-power MCU
· Dual channel
· K, T and J type thermocouples supported
· Resolution up to 0.01℃
· Factory accuracy ±(0.3%|t|+0.40)℃
· Accuracy up to ±0.1℃ after point calibration
Specifications:
Model | YET-620 | YET-620L |
Channel | 2 | |
Record function | No | Yes |
Support probe type | K, T, J type thermocouple | |
Unit | ℃,℉ | |
Measuring range | K type: -200~1370℃ T type: -200~400℃ J type: -200~1200℃ | |
Resolution | 0.01℃(-200.00~999.99℃) 0.1℃(1000.0~1370.0℃) | |
Native accuracy | ±(0.3%|t|+0.40)℃ | |
Measuring rate | 2 times/second | |
User calibration method | Multi-point calibration | |
Storage capacity | No | 20000 sets of measured values |
Record sampling interval | No | 1~86399 seconds adjustable |
Output file format | No | txt, csv, xls, dlg |
Compatible system | No | Windows XP/Vista/7/8/10 |
Display | Dot matrix LCD screen with backlight | |
Operating temperature | -10~50℃(non-condensing) | |
Storage temperature | -20~60℃(without battery) | |
Power supply | 3 pcs of 1.5V AAA alkaline batteries 3 pcs of 1.2V AAA rechargeable batteries 5V USB (not recommended) | |
Battery life | About 190 hours (conditions: the instrument continues to work, the backlight is off, the battery capacity is 1200mAh, and the ambient temperature is 25℃) | |
Protection class | IP52 | |
Dimensions | 174*73*40mm | |
Weight | About 200g (excluding batteries and probes) | |
Warranty | 12 months |
Features:
· 32-bit high-speed low-power MCU
· Dual channel
· K, T and J type thermocouples supported
· Resolution up to 0.01℃
· Factory accuracy ±(0.3%|t|+0.40)℃
· Accuracy up to ±0.1℃ after point calibration
Specifications:
Model | YET-620 | YET-620L |
Channel | 2 | |
Record function | No | Yes |
Support probe type | K, T, J type thermocouple | |
Unit | ℃,℉ | |
Measuring range | K type: -200~1370℃ T type: -200~400℃ J type: -200~1200℃ | |
Resolution | 0.01℃(-200.00~999.99℃) 0.1℃(1000.0~1370.0℃) | |
Native accuracy | ±(0.3%|t|+0.40)℃ | |
Measuring rate | 2 times/second | |
User calibration method | Multi-point calibration | |
Storage capacity | No | 20000 sets of measured values |
Record sampling interval | No | 1~86399 seconds adjustable |
Output file format | No | txt, csv, xls, dlg |
Compatible system | No | Windows XP/Vista/7/8/10 |
Display | Dot matrix LCD screen with backlight | |
Operating temperature | -10~50℃(non-condensing) | |
Storage temperature | -20~60℃(without battery) | |
Power supply | 3 pcs of 1.5V AAA alkaline batteries 3 pcs of 1.2V AAA rechargeable batteries 5V USB (not recommended) | |
Battery life | About 190 hours (conditions: the instrument continues to work, the backlight is off, the battery capacity is 1200mAh, and the ambient temperature is 25℃) | |
Protection class | IP52 | |
Dimensions | 174*73*40mm | |
Weight | About 200g (excluding batteries and probes) | |
Warranty | 12 months |