Adopt new super monolithic sensor technology - accurate, fast, stable and reliable.
♦ Sensitivity: unparalleled sensor design and processing technology ensure the sensitivity of micro-weighting results
♦ Precision: Particular super monolithic sensor technology ensures the accuracy, stability and consistency of weighing results.
♦ High-Speed: The sensor technology of horizontal bar, combined with excellent circuit design and software algorithm, meets the requirements of rapid weighing in the laboratory
Compliance with 21CFR Part 11 - full traceability
♦ Designed in accordance with FDA data integrity principles to achieve attributable, legible, contemporaneous, original, and accurate data (ALCOA).
♦ User administration: Three-level user administration through access control
♦ Electronic Signature: The users electronic signature can be used to sign the final report of the weighing operation.
♦ Audit Trail and Weighing Log: An audit trail is a tamper-proof electronic log file with a timestamp that allows the reconstruction of events related to the creation, modification, and/or deletion of records.
♦ Data transmission security; Electronic records should be protected from any tampering.
♦ Data output meets GLP/GMP requirements
Operating system with full touch screen
♦ Operation requirement is concise and clear, so customers can conveniently operate the balance and directly read the results on the screen to have a wonderful experience. At the same time, it is necessary to consider the special requirements of users in special industries, such as non-contact operation, etc.
Adopt automatic calibration and adjustment technology
♦ isoCAL automatic internal calibration and adjustment function, automatically triggered by temperature and time, fully ensure the accuracy of weighing results.
Adopt automatic door technology (optional)
♦ The technology of automatically opening and closing door is not only to improve customer experience satisfaction, but also necessary to consider the requirements of non-contact weighing in special industries, so as to achieve the goal of not contacting the balance during the weighing operation. Besides, The balance has a function of memorizing door position.
Fully automatic electrostatic removal technology (optional)
♦ Built-in ionizer can automatically eliminate the effect of static electricity on weighing
Built-in multi-applications
♦ Built-in multi-applications, print output, & data output meet GLP/GMP requirements
Standard communication interface
♦ Automatically identify the printer of D&T
♦ Standard RS232, easy to connect with peripherals
♦ PC connection function not only is easy to connect to PC, but also can directly transfer weighing data to spreadsheets (Excel)
Standard USB-C interface for data storage and export functions
Parameters:
Model | XE1035P | XE1055P | XE1085P | XE2035P | XE2055P | XE2085P | |
Max capacity(Max)(g) | 31/120 | 51/120 | 81/120 | 31/220 | 51/220 | 81/220 | |
Readability(d)(mg) | 0.01/0.1 | 0.01/0.1 | 0.01/0.1 | 0.01/0.1 | 0.01/0.1 | 0.01/0.1 | |
Repeatability(5% load) | |||||||
Tolerance(mg) | 0.01/0.1 | 0.01/0.1 | 0.01/0.1 | 0.01/0.1 | 0.01/0.1 | 0.01/0.1 | |
Typical value(mg) | 0.02/0.2 | 0.02/0.2 | 0.02/0.2 | 0.02/0.2 | 0.02/0.2 | 0.02/0.2 | |
Repeatability(approx. 100% load) | |||||||
Tolerance(mg) | 0.02/0.1 | 0.02/0.1 | 0.02/0.1 | 0.02/0.1 | 0.02/0.1 | 0.02/0.1 | |
Typical value(mg) | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | |
Linearity deviation | |||||||
Tolerance(mg) | 0.02/0.1 | 0.02/0.1 | 0.02/0.1 | 0.02/0.1 | 0.02/0.1 | 0.02/0.1 | |
Typical value(mg) | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | |
Off-center load deviation ( positions according to OIML R76) | |||||||
Test weight(g) | 20/100 | 50/100 | 50/100 | 20/100 | 20/100 | 50/100 | |
Tolerance(mg) | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | |
Typical value(mg) | 0.05/0.3 | 0.05/0.3 | 0.05/0.3 | 0.05/0.3 | 0.05/0.3 | 0.05/0.3 | |
Sensitivity drift (+10℃~+30℃) | 8 ppm/K | ||||||
Tare max capacity:<100% max capacity | |||||||
Accuracy class | Ⅰ( according to Directive 2014 | 31 | EU) | ||||||
Verification scale interval(e)(mg) ( according to Directive 2014 | 31 | EU) | 0.1/1 | 0.1/1 | 0.1/1 | 0.1/1 | 0.1/1 | 0.1/1 | |
Minimum load (mg) ( according to Directive 2014 | 31 | EU) | 1 | 1 | 1 | 1 | 1 | 1 | |
Minimum initial weighing :according to USP(United States Pharmacopeia) Chap. 41 | |||||||
Optimum minimum initial weighing(mg) | 1/10 | 1/10 | 1/10 | 1/10 | 1/10 | 1/10 | |
Typical minimum initial weighing(mg) | 0.82/8.2 | 0.82/8.2 | 0.82/8.2 | 0.82/8.2 | 0.82/8.2 | 0.82/8.2 | |
Typical stabilization time(s) | 5/3 | 5/3 | 5/3 | 5/3 | 5/3 | 5/3 | |
Typical measurement time(s) | 7/5 | 7/5 | 7/5 | 7/5 | 7/5 | 7/5 | |
Recommended calibration weight | |||||||
External calibrated test weight(g) | 20/100 | 50/100 | 50/100 | 20/100/200 | 50/100/200 | 50/100/200 | |
Accuracy class (according to OIML R111-1) | E1 | E1 | E1 | E1 | E1 | E1 |
Adopt new super monolithic sensor technology - accurate, fast, stable and reliable.
♦ Sensitivity: unparalleled sensor design and processing technology ensure the sensitivity of micro-weighting results
♦ Precision: Particular super monolithic sensor technology ensures the accuracy, stability and consistency of weighing results.
♦ High-Speed: The sensor technology of horizontal bar, combined with excellent circuit design and software algorithm, meets the requirements of rapid weighing in the laboratory
Compliance with 21CFR Part 11 - full traceability
♦ Designed in accordance with FDA data integrity principles to achieve attributable, legible, contemporaneous, original, and accurate data (ALCOA).
♦ User administration: Three-level user administration through access control
♦ Electronic Signature: The users electronic signature can be used to sign the final report of the weighing operation.
♦ Audit Trail and Weighing Log: An audit trail is a tamper-proof electronic log file with a timestamp that allows the reconstruction of events related to the creation, modification, and/or deletion of records.
♦ Data transmission security; Electronic records should be protected from any tampering.
♦ Data output meets GLP/GMP requirements
Operating system with full touch screen
♦ Operation requirement is concise and clear, so customers can conveniently operate the balance and directly read the results on the screen to have a wonderful experience. At the same time, it is necessary to consider the special requirements of users in special industries, such as non-contact operation, etc.
Adopt automatic calibration and adjustment technology
♦ isoCAL automatic internal calibration and adjustment function, automatically triggered by temperature and time, fully ensure the accuracy of weighing results.
Adopt automatic door technology (optional)
♦ The technology of automatically opening and closing door is not only to improve customer experience satisfaction, but also necessary to consider the requirements of non-contact weighing in special industries, so as to achieve the goal of not contacting the balance during the weighing operation. Besides, The balance has a function of memorizing door position.
Fully automatic electrostatic removal technology (optional)
♦ Built-in ionizer can automatically eliminate the effect of static electricity on weighing
Built-in multi-applications
♦ Built-in multi-applications, print output, & data output meet GLP/GMP requirements
Standard communication interface
♦ Automatically identify the printer of D&T
♦ Standard RS232, easy to connect with peripherals
♦ PC connection function not only is easy to connect to PC, but also can directly transfer weighing data to spreadsheets (Excel)
Standard USB-C interface for data storage and export functions
Parameters:
Model | XE1035P | XE1055P | XE1085P | XE2035P | XE2055P | XE2085P | |
Max capacity(Max)(g) | 31/120 | 51/120 | 81/120 | 31/220 | 51/220 | 81/220 | |
Readability(d)(mg) | 0.01/0.1 | 0.01/0.1 | 0.01/0.1 | 0.01/0.1 | 0.01/0.1 | 0.01/0.1 | |
Repeatability(5% load) | |||||||
Tolerance(mg) | 0.01/0.1 | 0.01/0.1 | 0.01/0.1 | 0.01/0.1 | 0.01/0.1 | 0.01/0.1 | |
Typical value(mg) | 0.02/0.2 | 0.02/0.2 | 0.02/0.2 | 0.02/0.2 | 0.02/0.2 | 0.02/0.2 | |
Repeatability(approx. 100% load) | |||||||
Tolerance(mg) | 0.02/0.1 | 0.02/0.1 | 0.02/0.1 | 0.02/0.1 | 0.02/0.1 | 0.02/0.1 | |
Typical value(mg) | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | |
Linearity deviation | |||||||
Tolerance(mg) | 0.02/0.1 | 0.02/0.1 | 0.02/0.1 | 0.02/0.1 | 0.02/0.1 | 0.02/0.1 | |
Typical value(mg) | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | |
Off-center load deviation ( positions according to OIML R76) | |||||||
Test weight(g) | 20/100 | 50/100 | 50/100 | 20/100 | 20/100 | 50/100 | |
Tolerance(mg) | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | 0.03/0.2 | |
Typical value(mg) | 0.05/0.3 | 0.05/0.3 | 0.05/0.3 | 0.05/0.3 | 0.05/0.3 | 0.05/0.3 | |
Sensitivity drift (+10℃~+30℃) | 8 ppm/K | ||||||
Tare max capacity:<100% max capacity | |||||||
Accuracy class | Ⅰ( according to Directive 2014 | 31 | EU) | ||||||
Verification scale interval(e)(mg) ( according to Directive 2014 | 31 | EU) | 0.1/1 | 0.1/1 | 0.1/1 | 0.1/1 | 0.1/1 | 0.1/1 | |
Minimum load (mg) ( according to Directive 2014 | 31 | EU) | 1 | 1 | 1 | 1 | 1 | 1 | |
Minimum initial weighing :according to USP(United States Pharmacopeia) Chap. 41 | |||||||
Optimum minimum initial weighing(mg) | 1/10 | 1/10 | 1/10 | 1/10 | 1/10 | 1/10 | |
Typical minimum initial weighing(mg) | 0.82/8.2 | 0.82/8.2 | 0.82/8.2 | 0.82/8.2 | 0.82/8.2 | 0.82/8.2 | |
Typical stabilization time(s) | 5/3 | 5/3 | 5/3 | 5/3 | 5/3 | 5/3 | |
Typical measurement time(s) | 7/5 | 7/5 | 7/5 | 7/5 | 7/5 | 7/5 | |
Recommended calibration weight | |||||||
External calibrated test weight(g) | 20/100 | 50/100 | 50/100 | 20/100/200 | 50/100/200 | 50/100/200 | |
Accuracy class (according to OIML R111-1) | E1 | E1 | E1 | E1 | E1 | E1 |