Availability: | |
---|---|
Quantity: | |
Adopt new super monolithic sensor technology - accurate, fast, stable and reliable.
♦ Sensitivity: unparalleled sensor design and processing technology ensure the sensitivity of micro-weighting results
♦ Precision: Particular super monolithic sensor technology ensures the accuracy, stability and consistency of weighing results.
♦ High-Speed: The sensor technology of horizontal bar, combined with excellent circuit design and software algorithm, meets the requirements of rapid weighing in the laboratory
Compliance with 21CFR Part 11 - full traceability
♦ Designed in accordance with FDA data integrity principles to achieve attributable, legible, contemporaneous, original, and accurate data (ALCOA).
♦ User administration: Three-level user administration through access control
♦ Electronic Signature: The user''s electronic signature can be used to sign the final report of the weighing operation.
♦ Audit Trail and Weighing Log: An audit trail is a tamper-proof electronic log file with a timestamp that allows the reconstruction of events related to the creation, modification, and/or deletion of records.
♦ Data transmission security; Electronic records should be protected from any tampering.
♦ Data output meets GLP/GMP requirements
Operating system with full touch screen
♦ Operation requirement is concise and clear, so customers can conveniently operate the balance and directly read the results on the screen to have a wonderful experience. At the same time, it is necessary to consider the special requirements of users in special industries, such as non-contact operation, etc.
Adopt automatic calibration and adjustment technology
♦ isoCAL automatic internal calibration and adjustment function, automatically triggered by temperature and time, fully ensure the accuracy of weighing results.
Adopt automatic door technology (optional)
♦ The technology of automatically opening and closing door is not only to improve customer experience satisfaction, but also necessary to consider the requirements of non-contact weighing in special industries, so as to achieve the goal of not contacting the balance during the weighing operation. Besides, the balance has a function of memorizing door position.
Fully automatic electrostatic removal technology (optional)
♦ Built-in ionizer can automatically eliminate the effect of static electricity on weighing
Built-in multi-applications
♦ Built-in multi-applications, print output, & data output meet GLP/GMP requirements
Standard communication interface
♦ Automatically identify the printer of D&T
♦ Standard RS232, easy to connect with peripherals
♦ PC connection function not only is easy to connect to PC, but also can directly transfer weighing data to spreadsheets (Excel)
Standard USB-C interface for data storage and export functions
Parameters:
Model | XE305S | XE505S | XE805S | XE1205S | XE2205S |
Max capacity(Max) | 31g | 51g | 81g | 120 | 220 |
Readability(d) | 0.01mg | 0.01mg | 0.01mg | 0.01mg | 0.01mg |
Repeatability(5% load) | |||||
Tolerance | 0.01mg | 0.01mg | 0.01mg | 0.015mg | 0.02mg |
Typical value | 0.02mg | 0.02mg | 0.02mg | 0.025mg | 0.03mg |
Repeatability(approx. 100% load) | |||||
Tolerance | 0.015mg | 0.015mg | 0.015mg | 0.02mg | 0.025mg |
Typical value | 0.02mg | 0.02mg | 0.03mg | 0.03mg | 0.05mg |
Linearity deviation | |||||
Tolerance | 0.015mg | 0.015mg | 0.015mg | 0.02mg | 0.03mg |
Typical value | 0.02mg | 0.02mg | 0.02mg | 0.03mg | 0.03mg |
Off-center load deviation ( positions according to OIML R76) | |||||
Test weight | 20g | 50g | 50g | 100g | 200g |
Tolerance | 0.02mg | 0.02mg | 0.03mg | 0.04mg | 0.04mg |
Typical value | 0.05mg | 0.05mg | 0.05mg | 0.06mg | 0.08mg |
Sensitivity drift (+10℃~+30℃) | 8 ppm/K | ||||
Tare max capacity:<100% max capacity | |||||
Accuracy class | Ⅰ( according to Directive 2014 | 31 | EU) | ||||
Verification scale interval(e) ( according to Directive 2014 | 31 | EU) | 0.1mg | 0.1mg | 0.1mg | 0.1mg | 0.1mg |
Minimum load ( according to Directive 2014 | 31 | EU) | 1mg | 1mg | 1mg | 1mg | 1mg |
Minimum initial weighing :according to USP(United States Pharmacopeia) Chap. 41 | |||||
Optimum minimum initial weighing | 0.82mg | 0.82mg | 0.82mg | 0.82mg | 0.82mg |
Typical minimum initial weighing | 1.3mg | 1.3mg | 1.3mg | 1.3mg | 1.3mg |
Typical stabilization time | 3s | 3s | 3s | 3s | 5s |
Typical measurement time | 5s | 5s | 5s | 5s | 8s |
Recommended calibration weight | |||||
External calibrated test weight | 20g | 50g | 50g | 100g | 200g |
Accuracy class (according to OIML R111-1) | E1 | E1 | E1 | E1 | E1 |
Dimensions | |||||
L x W x H | 240mm×430mm×380mm | ||||
Weighing pan | 85mm×85mm | ||||
Weighing chamber height | 248mm | ||||
Net weight | approx. 9.86kg | ||||
Ambient conditions | |||||
Operation temperature | 18℃~23℃ | ||||
Relative humidity | 50%RH~75%RH | ||||
Warm-up temperature fluctuation | ≤1°C/h | ||||
Power supply | 100V-240VAC 50HZ/60HZ 1.0A-0.5A |
Adopt new super monolithic sensor technology - accurate, fast, stable and reliable.
♦ Sensitivity: unparalleled sensor design and processing technology ensure the sensitivity of micro-weighting results
♦ Precision: Particular super monolithic sensor technology ensures the accuracy, stability and consistency of weighing results.
♦ High-Speed: The sensor technology of horizontal bar, combined with excellent circuit design and software algorithm, meets the requirements of rapid weighing in the laboratory
Compliance with 21CFR Part 11 - full traceability
♦ Designed in accordance with FDA data integrity principles to achieve attributable, legible, contemporaneous, original, and accurate data (ALCOA).
♦ User administration: Three-level user administration through access control
♦ Electronic Signature: The user''s electronic signature can be used to sign the final report of the weighing operation.
♦ Audit Trail and Weighing Log: An audit trail is a tamper-proof electronic log file with a timestamp that allows the reconstruction of events related to the creation, modification, and/or deletion of records.
♦ Data transmission security; Electronic records should be protected from any tampering.
♦ Data output meets GLP/GMP requirements
Operating system with full touch screen
♦ Operation requirement is concise and clear, so customers can conveniently operate the balance and directly read the results on the screen to have a wonderful experience. At the same time, it is necessary to consider the special requirements of users in special industries, such as non-contact operation, etc.
Adopt automatic calibration and adjustment technology
♦ isoCAL automatic internal calibration and adjustment function, automatically triggered by temperature and time, fully ensure the accuracy of weighing results.
Adopt automatic door technology (optional)
♦ The technology of automatically opening and closing door is not only to improve customer experience satisfaction, but also necessary to consider the requirements of non-contact weighing in special industries, so as to achieve the goal of not contacting the balance during the weighing operation. Besides, the balance has a function of memorizing door position.
Fully automatic electrostatic removal technology (optional)
♦ Built-in ionizer can automatically eliminate the effect of static electricity on weighing
Built-in multi-applications
♦ Built-in multi-applications, print output, & data output meet GLP/GMP requirements
Standard communication interface
♦ Automatically identify the printer of D&T
♦ Standard RS232, easy to connect with peripherals
♦ PC connection function not only is easy to connect to PC, but also can directly transfer weighing data to spreadsheets (Excel)
Standard USB-C interface for data storage and export functions
Parameters:
Model | XE305S | XE505S | XE805S | XE1205S | XE2205S |
Max capacity(Max) | 31g | 51g | 81g | 120 | 220 |
Readability(d) | 0.01mg | 0.01mg | 0.01mg | 0.01mg | 0.01mg |
Repeatability(5% load) | |||||
Tolerance | 0.01mg | 0.01mg | 0.01mg | 0.015mg | 0.02mg |
Typical value | 0.02mg | 0.02mg | 0.02mg | 0.025mg | 0.03mg |
Repeatability(approx. 100% load) | |||||
Tolerance | 0.015mg | 0.015mg | 0.015mg | 0.02mg | 0.025mg |
Typical value | 0.02mg | 0.02mg | 0.03mg | 0.03mg | 0.05mg |
Linearity deviation | |||||
Tolerance | 0.015mg | 0.015mg | 0.015mg | 0.02mg | 0.03mg |
Typical value | 0.02mg | 0.02mg | 0.02mg | 0.03mg | 0.03mg |
Off-center load deviation ( positions according to OIML R76) | |||||
Test weight | 20g | 50g | 50g | 100g | 200g |
Tolerance | 0.02mg | 0.02mg | 0.03mg | 0.04mg | 0.04mg |
Typical value | 0.05mg | 0.05mg | 0.05mg | 0.06mg | 0.08mg |
Sensitivity drift (+10℃~+30℃) | 8 ppm/K | ||||
Tare max capacity:<100% max capacity | |||||
Accuracy class | Ⅰ( according to Directive 2014 | 31 | EU) | ||||
Verification scale interval(e) ( according to Directive 2014 | 31 | EU) | 0.1mg | 0.1mg | 0.1mg | 0.1mg | 0.1mg |
Minimum load ( according to Directive 2014 | 31 | EU) | 1mg | 1mg | 1mg | 1mg | 1mg |
Minimum initial weighing :according to USP(United States Pharmacopeia) Chap. 41 | |||||
Optimum minimum initial weighing | 0.82mg | 0.82mg | 0.82mg | 0.82mg | 0.82mg |
Typical minimum initial weighing | 1.3mg | 1.3mg | 1.3mg | 1.3mg | 1.3mg |
Typical stabilization time | 3s | 3s | 3s | 3s | 5s |
Typical measurement time | 5s | 5s | 5s | 5s | 8s |
Recommended calibration weight | |||||
External calibrated test weight | 20g | 50g | 50g | 100g | 200g |
Accuracy class (according to OIML R111-1) | E1 | E1 | E1 | E1 | E1 |
Dimensions | |||||
L x W x H | 240mm×430mm×380mm | ||||
Weighing pan | 85mm×85mm | ||||
Weighing chamber height | 248mm | ||||
Net weight | approx. 9.86kg | ||||
Ambient conditions | |||||
Operation temperature | 18℃~23℃ | ||||
Relative humidity | 50%RH~75%RH | ||||
Warm-up temperature fluctuation | ≤1°C/h | ||||
Power supply | 100V-240VAC 50HZ/60HZ 1.0A-0.5A |