Availability: | |
---|---|
Quantity: | |
Features:
LCD display, easy operation; safe and reliable to use.
Water bath provides gentle heat.
Accommodates sample in tubes(diameter 10~29mm), volume(1~ 50ml).
12positions, each position is numbered.
Blowing each sample independently.
With liquid-level sensor, have alarming function when dry heating.
The lifting needle valve controls the gas consumption at each position.
All parts are anti-corrosion, durable in use, easy to clean.
Main application fields:
Analysis of pesticide residues: vegetables, fruits, cereals, plant tissue.
Environmental analysis: drinking water, groundwater and polluted water.
Biological analysis: such as hormone analysis, sample preparation of liquid phase and gas phase and mass spectrometry analysis.
Food and beverage: such as milk, wine, beer, etc.
Pharmaceutical drug testing: such as traditional Chinese medicine pharmaceutical, drug screening.
Normal Operating Condition:
Ambient temp:0°C ~ 35°C
Relative humidity :≤70%
Power supply:AC220V~5A 50-60Hz
Parameters and performance:
Model | WD1000 |
Temp. range | RT.+5℃~99℃ |
Time range | 1min~99h59min/∞ |
Display accuracy | ±0.1℃ |
Temp accuracy | ≤±1℃ |
Temp uniformity (@60℃) | ≤±1℃ |
Heating time(40℃-99℃) | ≤30min |
Samples position | 12positions |
Tube size | |
Max vertical travel | 200mm |
Max gas pressure | 200Kpa |
Max gas usage | 15L/min |
Gas joint diameter | φ8 |
Power | 1000W |
Fuse | 250V 8A φ5×20 |
Dimension(mm) | 390×300×850 |
Weight(kg) | 10 |
Features:
LCD display, easy operation; safe and reliable to use.
Water bath provides gentle heat.
Accommodates sample in tubes(diameter 10~29mm), volume(1~ 50ml).
12positions, each position is numbered.
Blowing each sample independently.
With liquid-level sensor, have alarming function when dry heating.
The lifting needle valve controls the gas consumption at each position.
All parts are anti-corrosion, durable in use, easy to clean.
Main application fields:
Analysis of pesticide residues: vegetables, fruits, cereals, plant tissue.
Environmental analysis: drinking water, groundwater and polluted water.
Biological analysis: such as hormone analysis, sample preparation of liquid phase and gas phase and mass spectrometry analysis.
Food and beverage: such as milk, wine, beer, etc.
Pharmaceutical drug testing: such as traditional Chinese medicine pharmaceutical, drug screening.
Normal Operating Condition:
Ambient temp:0°C ~ 35°C
Relative humidity :≤70%
Power supply:AC220V~5A 50-60Hz
Parameters and performance:
Model | WD1000 |
Temp. range | RT.+5℃~99℃ |
Time range | 1min~99h59min/∞ |
Display accuracy | ±0.1℃ |
Temp accuracy | ≤±1℃ |
Temp uniformity (@60℃) | ≤±1℃ |
Heating time(40℃-99℃) | ≤30min |
Samples position | 12positions |
Tube size | |
Max vertical travel | 200mm |
Max gas pressure | 200Kpa |
Max gas usage | 15L/min |
Gas joint diameter | φ8 |
Power | 1000W |
Fuse | 250V 8A φ5×20 |
Dimension(mm) | 390×300×850 |
Weight(kg) | 10 |