Availability: | |
---|---|
Quantity: | |
Main feature
· Accurate weight measurement
The whole machine has super high resolution and very good repeatability, through the auto-centering pan to eliminate partial load , to ensure that you get the best measurement performance and traceability of weighing results.
· Measurement comparison of full range mg to ton weights
· Cover the full range measurement and mass calibration of class M to class E1 weights
· Auto-centering device (some models)
· Improve the accuracy of the weighing results, eliminate the partial load error, and accurately locate all types of items to the center of gravity, without manually adjusting the position of the weight on the scale plate.Electromechanical separation design (some models)
Mobile and separable display operation terminal, isolate the interference of electrical noise to the sensitive analog circuit; shorten stability time, improve the repeatability, and ensure the accuracy of measurement.
Parameters:
Model | Nominal Weight | Maximum Permissible Errors | Readability(d) | Specification | repeatability error |
XE36 | 1g | 0.03mg | 0.003mg | 31g/0.001mg | ±0 .002mg |
2g | 0.04mg | 0.004mg | |||
5g | 0.05mg | 0.005mg | |||
10g | 0.06mg | 0.006mg | |||
20g | 0.08mg | 0.008mg | |||
XE2205S | 50g | 0.1mg | 0.01mg | 220g/0.01mg | ±0 .02mg |
100g | 0.16mg | 0.016mg | |||
200g | 0.3mg | 0.03mg | |||
XE505S-2 | 500g | 0.8mg | 0.08mg | 500g/0.02mg | ±0 .04mg |
XE2204S | 1kg | 1.6mg | 0.16mg | 2000g/0. 1mg | ±0 .2mg |
2kg | 3mg | 0.3mg | |||
XE5204S-2 | 5kg | 8mg | 0.8mg | 5000g/0.2mg | ±0 .4mg |
XE26 | 10kg | 16mg | 1.6mg | 26kg/1mg | ±2mg |
20kg | 30mg | 3mg |
Main feature
· Accurate weight measurement
The whole machine has super high resolution and very good repeatability, through the auto-centering pan to eliminate partial load , to ensure that you get the best measurement performance and traceability of weighing results.
· Measurement comparison of full range mg to ton weights
· Cover the full range measurement and mass calibration of class M to class E1 weights
· Auto-centering device (some models)
· Improve the accuracy of the weighing results, eliminate the partial load error, and accurately locate all types of items to the center of gravity, without manually adjusting the position of the weight on the scale plate.Electromechanical separation design (some models)
Mobile and separable display operation terminal, isolate the interference of electrical noise to the sensitive analog circuit; shorten stability time, improve the repeatability, and ensure the accuracy of measurement.
Parameters:
Model | Nominal Weight | Maximum Permissible Errors | Readability(d) | Specification | repeatability error |
XE36 | 1g | 0.03mg | 0.003mg | 31g/0.001mg | ±0 .002mg |
2g | 0.04mg | 0.004mg | |||
5g | 0.05mg | 0.005mg | |||
10g | 0.06mg | 0.006mg | |||
20g | 0.08mg | 0.008mg | |||
XE2205S | 50g | 0.1mg | 0.01mg | 220g/0.01mg | ±0 .02mg |
100g | 0.16mg | 0.016mg | |||
200g | 0.3mg | 0.03mg | |||
XE505S-2 | 500g | 0.8mg | 0.08mg | 500g/0.02mg | ±0 .04mg |
XE2204S | 1kg | 1.6mg | 0.16mg | 2000g/0. 1mg | ±0 .2mg |
2kg | 3mg | 0.3mg | |||
XE5204S-2 | 5kg | 8mg | 0.8mg | 5000g/0.2mg | ±0 .4mg |
XE26 | 10kg | 16mg | 1.6mg | 26kg/1mg | ±2mg |
20kg | 30mg | 3mg |