main feature:
Using four LED light sources of 420nm, 470nm, 620nm and 700nm, it has long life and high precision;
Built-in measurement methods: ammonia, high concentration COD, low concentration COD, total phosphorus, total nitrogen;
Adopting high-definition LCD screen, clear display and friendly operation interface;
Supports functions such as automatic shutdown, power-off protection and factory reset;
Support firmware upgrade function, allowing function expansion and personalized requirements;
IP65 protection level.
Intelligent detection:
Intelligently determines the end point and supports automatic reading;
Set the dilution ratio and automatically calculate the original concentration of the sample;
Optional built-in calibration curve or customized calibration curve (2~5 points);
Supports recalibration of a certain calibration point.
Data management:
Support data storage (500 groups each), review, deletion, transmission and printing;
Comply with GLP and achieve data traceability;
Built-in small printer, can print automatically, and the printing format is optional;
Support U disk data export;
It has RS-232 and USB interfaces and can be connected to PC through special communication software to realize data transmission.
Specifications:
model | DGS-450 | |
Test items | Ammonia nitrogen, low concentration COD, high concentration COD, total phosphorus, total ammonia | |
Ammonia nitrogen | Measurement methods | Nessler's reagent method |
Measuring range | (0.000-10.00)mg/L, can be expanded to 100.0mg/L | |
error | 5% | |
Repeatability | ≤2% | |
stability | <0.200mg/L (20min) | |
The detection limit | ≤0.03mg/L | |
wavelength | 420nm | |
Need to be digested | / | |
Low concentration | Measurement methods | potassium dichromate method |
Measuring range | (0.000-150.0)mg/L | |
Error | ±8% | |
Repeatability | ≤3% | |
Stability | <6mg/L(20min) | |
Wavelength | 470nm | |
Whether to dissolve | Need to be digested | |
High concentration | Measurement methods | potassium dichromate method |
Measuring range | (0-1500)mg/L, expandable to 15000mg/L | |
Error | ±8% | |
Repeatability | ≤3% | |
Stability | <6mg/L(20min) | |
Wavelength | 620nm | |
Need to be digested | Need to be digested | |
total phosphorus | Weight measurement method | Molybdate spectrophotometry |
Measuring range | (0.000-1.000)mg/L, can be expanded to 10.00mg/L | |
error | 10% | |
Repeatability | ≤3% | |
stability | <0.050mg/L(20min) | |
The detection limit | ≤0.05mg/L | |
wavelength | 700nm | |
Whether to dissolve | Need to be digested | |
total nitrogen | Weight measurement method | Alkaline potassium persulfate digestion-sodium chromophore |
Measuring range | (0.000-30.00)mg/L, can be expanded to 300.0mg/L | |
error | ≤10mg/L: ±1 mg/L; | |
Repeatability | ≤3% | |
The detection limit | ≤1mg/L | |
wavelength | 420nm | |
Whether to dissolve | Need to be digested | |
Absorbance | Measuring range | (0.000~2.000)Abs |
wavelength | Measure wavelength | 420nm, 470nm, 620nm, 700nm |
Accuracy | ±4nm | |
Transmittance | Indication error | ±2% |
Repeatability | ≤ 0.5% | |
data storage | 500 sets of test results each | |
cuvette | 25mm colorimetric tube, 16mm colorimetric tube | |
power supply | Power adapter (input AC: (100~240)V, output: DC24V | |
Dimensions (mm); Weight (kg) | 302x205x122, 1.33 |
main feature:
Using four LED light sources of 420nm, 470nm, 620nm and 700nm, it has long life and high precision;
Built-in measurement methods: ammonia, high concentration COD, low concentration COD, total phosphorus, total nitrogen;
Adopting high-definition LCD screen, clear display and friendly operation interface;
Supports functions such as automatic shutdown, power-off protection and factory reset;
Support firmware upgrade function, allowing function expansion and personalized requirements;
IP65 protection level.
Intelligent detection:
Intelligently determines the end point and supports automatic reading;
Set the dilution ratio and automatically calculate the original concentration of the sample;
Optional built-in calibration curve or customized calibration curve (2~5 points);
Supports recalibration of a certain calibration point.
Data management:
Support data storage (500 groups each), review, deletion, transmission and printing;
Comply with GLP and achieve data traceability;
Built-in small printer, can print automatically, and the printing format is optional;
Support U disk data export;
It has RS-232 and USB interfaces and can be connected to PC through special communication software to realize data transmission.
Specifications:
model | DGS-450 | |
Test items | Ammonia nitrogen, low concentration COD, high concentration COD, total phosphorus, total ammonia | |
Ammonia nitrogen | Measurement methods | Nessler's reagent method |
Measuring range | (0.000-10.00)mg/L, can be expanded to 100.0mg/L | |
error | 5% | |
Repeatability | ≤2% | |
stability | <0.200mg/L (20min) | |
The detection limit | ≤0.03mg/L | |
wavelength | 420nm | |
Need to be digested | / | |
Low concentration | Measurement methods | potassium dichromate method |
Measuring range | (0.000-150.0)mg/L | |
Error | ±8% | |
Repeatability | ≤3% | |
Stability | <6mg/L(20min) | |
Wavelength | 470nm | |
Whether to dissolve | Need to be digested | |
High concentration | Measurement methods | potassium dichromate method |
Measuring range | (0-1500)mg/L, expandable to 15000mg/L | |
Error | ±8% | |
Repeatability | ≤3% | |
Stability | <6mg/L(20min) | |
Wavelength | 620nm | |
Need to be digested | Need to be digested | |
total phosphorus | Weight measurement method | Molybdate spectrophotometry |
Measuring range | (0.000-1.000)mg/L, can be expanded to 10.00mg/L | |
error | 10% | |
Repeatability | ≤3% | |
stability | <0.050mg/L(20min) | |
The detection limit | ≤0.05mg/L | |
wavelength | 700nm | |
Whether to dissolve | Need to be digested | |
total nitrogen | Weight measurement method | Alkaline potassium persulfate digestion-sodium chromophore |
Measuring range | (0.000-30.00)mg/L, can be expanded to 300.0mg/L | |
error | ≤10mg/L: ±1 mg/L; | |
Repeatability | ≤3% | |
The detection limit | ≤1mg/L | |
wavelength | 420nm | |
Whether to dissolve | Need to be digested | |
Absorbance | Measuring range | (0.000~2.000)Abs |
wavelength | Measure wavelength | 420nm, 470nm, 620nm, 700nm |
Accuracy | ±4nm | |
Transmittance | Indication error | ±2% |
Repeatability | ≤ 0.5% | |
data storage | 500 sets of test results each | |
cuvette | 25mm colorimetric tube, 16mm colorimetric tube | |
power supply | Power adapter (input AC: (100~240)V, output: DC24V | |
Dimensions (mm); Weight (kg) | 302x205x122, 1.33 |