What should we pay attention to if the constant temperature and humidity incubator long-term power failure?

Views: 0     Author: Meditry Instrument Co., Ltd.      Publish Time: 2024-06-12      Origin: Site

Temperature And Humidity Incubators HWS-100 HWS-150 HWS-250 HWS-300 HWS-400

Some customers bought a constant temperature and humidity incubator to do the test after the power supply unplugged to stop making, in fact, this practice is not scientific. Has stopped using the constant temperature and humidity box users, at least one month should be energized 1-2 times, each time the constant temperature and humidity incubator running for about 10 minutes. Otherwise, once caused by the constant temperature and humidity box pipeline blockage or leakage, and then will fail.


Constant temperature and humidity incubator is ready to long time power outage should pay attention to a few problems:

1. First of all, use a clean rag to wipe the constant temperature and humidity incubator from inside to outside, there must be no water, in order to ensure that the box must be dry, you can set the temperature inside the constant temperature and humidity incubator to 45 ° C to run for about 1 hour, the box moisture thoroughly dry before power off.

2. When moving the constant temperature and humidity incubator, pay attention to vertical and parallel movement, try to avoid tilting, to prevent the compressor from dragging the cylinder. Try to constant temperature and humidity incubator placed in a ventilated dry place, avoid direct sunlight.

3. Because the refrigerant freezing point of constant temperature and humidity incubator is very low, so there is no need to worry about the refrigerant of the incubator will freeze and put the equipment in a place with high temperature.

4. Some friends think that if the constant temperature and humidity incubator will not be used for a long time, it is best to find a plastic bag to cover to prevent it from falling soil, this concept is not scientific. Because the indoor air contains a certain amount of water, if the plastic bag will be constant temperature and humidity incubator cover up, will make the constant temperature and humidity incubator absorbed moisture is difficult to emit, which will cause corrosion of the electrical components and damage to the metal components of the rust and so on. If you want to prevent the equipment from falling ash, you can use cotton cloth or tablecloth on the top of the incubator, regular cleaning cover cloth can be.


Meditry Instrument Co., Ltd., 2 hours drive from Shanghai, is specialized in exporting and supplying high quality laboratory equipment, medical equipments, petroleum oil and chemical testing instruments.

QUICK LINK

PRODUCTS

CONTACT
Tel: +86 510 8631 2055
Mobile: +86 139 188 11720 
E-mail:
sales@meditry.com
Address:
No.8223 Electronic Commerce Industry Park, Changjing Town,Jiangyin City, Jiangsu Province , P.R. China 214411
2024Copyright  Meditry Instrument Co., Ltd.