You are here: Home » News » Precautions for low temperature incubator

Precautions for low temperature incubator

Views: 0     Author: Meditry Instrument Co., Ltd.     Publish Time: 2024-06-21      Origin: Site

Cooled Incubator Low Temperature Incubator LRH Series

Low temperature incubator with refrigeration and heating two-way thermoregulation system, temperature controllable function, is biology, genetic engineering, medicine, health and epidemic prevention, environmental protection, agriculture, forestry and animal husbandry and other industries, scientific research institutions, colleges and universities, production units or departments of the laboratory of the important experimental equipment, is widely used in low-temperature constant-temperature test, cultivation test, environmental testing, etc.. Low-temperature incubator controller circuit consists of a temperature sensor, voltage comparator and control implementation circuit.

Low temperature incubator main features:

1, microcomputer intelligent temperature control instrument, with setting, measuring temperature double digital display and PID self-tuning function, temperature control *, reliable.

2、Double door structure, the inner door adopts tempered glass door, observe the situation inside the box does not affect the temperature inside the box.

3、Studio adopts mirror stainless steel, the shelf is easy to disassemble, easy to clean and adjust the interval height.

4, when the tempered glass door is opened, the breeze circulation automatically stops, so that the studio temperature impact is reduced to the * limit.

5, modular refrigeration device, configured with delayed start, high and low pressure multiple protection, with the use of safe, stable operation, easy repair and maintenance, fast temperature rise and fall and so on.

Precautions for low temperature incubator:

1, low-temperature incubator as far as possible to be installed in the place where the temperature and humidity changes are small, the use of three-pronged plug? The socket should be properly grounded.

2, low-temperature incubator before starting should be fully familiar with and understand the composition of the supporting instruments, instrumentation manual, master the correct method of use.

3、Frequently check the gas circuit for air leakage.

4, low-temperature incubator has a power failure protection function, so the compressor after the shutdown to start again for about one and a half minutes, so as to better protect the compressor.

5, low-temperature incubator in handling, maintenance, maintenance should avoid collision and shaking vibration, * tilt should be less than 45 degrees.

6, a long time to stop using should be closed when the total power supply and equipment at the back of the power switch.? At the same time, the low-temperature incubator should be avoided when working to open the door frequently to maintain temperature stability, while preventing dust and dirt into the work chamber.

7, the end of the culture to turn off the power switch, such as not immediately remove the experimental samples, please do not open the door.

8, low-temperature incubator should not be used in high voltage, high current, strong magnetic field and other abnormal environments, in strict accordance with the code of electrical safety practices.


Meditry Instrument Co., Ltd., 2 hours drive from Shanghai, is specialized in exporting and supplying high quality laboratory equipment, medical equipments, petroleum oil and chemical testing instruments.