Components:
LCD program controller
--99 cycles can be preset, 30 segments can be programmed, each segment has a setting time of 1~9999min (hours)
International brand compressor
Environmentally friendly fluorine-free refrigerant R134A
Independently developed water circulation system
--Double built-in water tanks, the auxiliary water tank enters the main water tank after preheating to prevent cold water from being pumped directly into the tank and affecting temperature and humidity fluctuations in the tank
--An additional external water storage tank with water shortage alarm can be used for one month at 25℃ and 60%RH after filling up.
Structure:
Outer box: high quality electrostatically sprayed cold rolled plate
Insulation layer: high-pressure polyurethane overall foaming
Inner wall: SUS304 brushed stainless steel
Door lock: The outer door is equipped with a key lock to prevent unauthorized persons from accessing the samples and affecting the test.
Verification hole: φ30mm
Casters: 4, movable and lockable
Observation window: hollow glass
Control System:
Control method: balanced temperature and humidity control
Air flow mode: forced vertical convection, uniform air duct system
Heating method: electric heating system
Refrigeration method: Compressor refrigeration system, unique automatic pressure relief technology, can work stably for a long time
Humidification method: independently developed electric steam humidification
Water supply method: automatic circulating water supply system, no special water and electricity requirements at the use site
Data management:
①Embedded printer (optional)
--Print temperature and humidity data in real time
②U disk (optional)
--Can save 250,000 data records, and supports exporting with a USB flash drive in an unchangeable file format for viewing and backup
③Multi-channel LCD paperless recorder (optional)
--Real-time recording of temperature and humidity, and data can be exported via USB flash drive
Safety protection:
Compressor overheat protection, compressor overpressure protection, compressor overload protection
Independent studio over-temperature protection
Humidification system water shortage protection
Humidification water shortage alarm system
Mobile phone SMS monitoring and alarm system (optional)
Technical parameter:
Model | LHS-100HC | LHS-150HC | LHS-250HC | LHS-300HC | LHS-400HC | |
Capacity(L) | 100 | 150 | 250 | 300 | 400 | |
Temperature(℃) | Control range | 5~65 | ||||
Resolution | 0.1 | |||||
Volatility | ± 0.5 | |||||
Evenness | 1.2 | |||||
Humidity(%RH) | Control range | 35~95%RH | ||||
Resolution | 0.1 | |||||
Volatility | Single point fluctuation ≤±1% RH; multi-point deviation ≤±3% RH; multi-point uniformity ≤5% RH | |||||
Evenness | ≤5%RH | |||||
Temperature and humidity data | Temperature at 9 o'clock, actual humidity measurement at 3 o'clock | |||||
Power (W) | 1530 | 1530 | 1530 | 1530 | 1530 | |
Power supply | 220VAC 50HZ | |||||
Inner box size (cm) | 45×43×55 | 45×43×80 | 50×43×105 | 55×50×110 | 60×55×113 | |
Carton size (cm) | 52×52×113 | 52×52×136 | 57×57×160 | 60×64×168 | 68×69×172 | |
Carrying bracket | 3 | 3 | 4 | 4 | 4 |
The performance parameter test under no-load conditions is: ambient temperature 20℃, ambient humidity 50%RH
Components:
LCD program controller
--99 cycles can be preset, 30 segments can be programmed, each segment has a setting time of 1~9999min (hours)
International brand compressor
Environmentally friendly fluorine-free refrigerant R134A
Independently developed water circulation system
--Double built-in water tanks, the auxiliary water tank enters the main water tank after preheating to prevent cold water from being pumped directly into the tank and affecting temperature and humidity fluctuations in the tank
--An additional external water storage tank with water shortage alarm can be used for one month at 25℃ and 60%RH after filling up.
Structure:
Outer box: high quality electrostatically sprayed cold rolled plate
Insulation layer: high-pressure polyurethane overall foaming
Inner wall: SUS304 brushed stainless steel
Door lock: The outer door is equipped with a key lock to prevent unauthorized persons from accessing the samples and affecting the test.
Verification hole: φ30mm
Casters: 4, movable and lockable
Observation window: hollow glass
Control System:
Control method: balanced temperature and humidity control
Air flow mode: forced vertical convection, uniform air duct system
Heating method: electric heating system
Refrigeration method: Compressor refrigeration system, unique automatic pressure relief technology, can work stably for a long time
Humidification method: independently developed electric steam humidification
Water supply method: automatic circulating water supply system, no special water and electricity requirements at the use site
Data management:
①Embedded printer (optional)
--Print temperature and humidity data in real time
②U disk (optional)
--Can save 250,000 data records, and supports exporting with a USB flash drive in an unchangeable file format for viewing and backup
③Multi-channel LCD paperless recorder (optional)
--Real-time recording of temperature and humidity, and data can be exported via USB flash drive
Safety protection:
Compressor overheat protection, compressor overpressure protection, compressor overload protection
Independent studio over-temperature protection
Humidification system water shortage protection
Humidification water shortage alarm system
Mobile phone SMS monitoring and alarm system (optional)
Technical parameter:
Model | LHS-100HC | LHS-150HC | LHS-250HC | LHS-300HC | LHS-400HC | |
Capacity(L) | 100 | 150 | 250 | 300 | 400 | |
Temperature(℃) | Control range | 5~65 | ||||
Resolution | 0.1 | |||||
Volatility | ± 0.5 | |||||
Evenness | 1.2 | |||||
Humidity(%RH) | Control range | 35~95%RH | ||||
Resolution | 0.1 | |||||
Volatility | Single point fluctuation ≤±1% RH; multi-point deviation ≤±3% RH; multi-point uniformity ≤5% RH | |||||
Evenness | ≤5%RH | |||||
Temperature and humidity data | Temperature at 9 o'clock, actual humidity measurement at 3 o'clock | |||||
Power (W) | 1530 | 1530 | 1530 | 1530 | 1530 | |
Power supply | 220VAC 50HZ | |||||
Inner box size (cm) | 45×43×55 | 45×43×80 | 50×43×105 | 55×50×110 | 60×55×113 | |
Carton size (cm) | 52×52×113 | 52×52×136 | 57×57×160 | 60×64×168 | 68×69×172 | |
Carrying bracket | 3 | 3 | 4 | 4 | 4 |
The performance parameter test under no-load conditions is: ambient temperature 20℃, ambient humidity 50%RH