Features:
lDesktop type, compact in size, with a minimum temperature of -40 degrees, the same size as icooler-2006, but with stronger cooling capacity. It can cool two small rotary evaporators. It can be used on the desktop or in a fume hood;
liCooler-4006 has an LED display with a display accuracy of 0.1, iCooler-4006+ and iCooler-4006P have a TFT display with a switchable display accuracy of 0.1/0.01/0.001;
lThe standard immersed circulation pump can realize external closed pipeline applications, and the optional liquid level controller can also realize constant temperature circulation applications in external open containers;
lOptional high-lift pressure pump, maximum lift 11m, maximum flow 23L/min;
lAfter icooler-4006+ and icooler-4006P are configured with heating functions, they can realize high and low temperature constant temperature functions, and iCooler-4006P can realize program control functions. After configuring the heating function, configure the three-level protection function at the same time. The first level of low liquid level protection, the second level of adjustable safety temperature protection, can cut off the heater power in time during dry burning, and the third level can set high and low temperature limits. When the detected temperature exceeds the set value, it will alarm and shut down. Both flammable and non-flammable liquids can be used.
Upgradeable functions:
lThe display curve shows;
lexternal temperature control;
lProgrammable control; slope/linear temperature rise control;
lPC monitoring software Labtemp;
lModbus RS485/R232 communication analog input and output;
lSwitching input and output; 2KW, 3KW heating power external equipment power supply;
lHigh pressure circulation pump.
Parameters:
Model | iCooler-4006 | iCooler-4006+ | iCooler-4006P |
Working temperature range (°C) | -40~40 | -40~100 | -40~100 |
Temperature stability (°C) | ±0.3 | ±0.05 | ±0.02 |
Cooling capacity(W) | 800(20℃) | 800(20℃) | 800(20℃) |
Heating capacity (W) | - | 1500 | 1500 |
Pump capacity flow rate (L/min) | 22 | 22 | 22 |
Pump pressure/suction(bar) | 0.3/0.2 | 0.3/0.2 | 0.3/0.2 |
Filling volume(L) | 5 | 4.5 | 6 |
dimensions WxDxH(mm) | 220X420X495 | 220X420X495 | 220X420X495 |
Features:
lDesktop type, compact in size, with a minimum temperature of -40 degrees, the same size as icooler-2006, but with stronger cooling capacity. It can cool two small rotary evaporators. It can be used on the desktop or in a fume hood;
liCooler-4006 has an LED display with a display accuracy of 0.1, iCooler-4006+ and iCooler-4006P have a TFT display with a switchable display accuracy of 0.1/0.01/0.001;
lThe standard immersed circulation pump can realize external closed pipeline applications, and the optional liquid level controller can also realize constant temperature circulation applications in external open containers;
lOptional high-lift pressure pump, maximum lift 11m, maximum flow 23L/min;
lAfter icooler-4006+ and icooler-4006P are configured with heating functions, they can realize high and low temperature constant temperature functions, and iCooler-4006P can realize program control functions. After configuring the heating function, configure the three-level protection function at the same time. The first level of low liquid level protection, the second level of adjustable safety temperature protection, can cut off the heater power in time during dry burning, and the third level can set high and low temperature limits. When the detected temperature exceeds the set value, it will alarm and shut down. Both flammable and non-flammable liquids can be used.
Upgradeable functions:
lThe display curve shows;
lexternal temperature control;
lProgrammable control; slope/linear temperature rise control;
lPC monitoring software Labtemp;
lModbus RS485/R232 communication analog input and output;
lSwitching input and output; 2KW, 3KW heating power external equipment power supply;
lHigh pressure circulation pump.
Parameters:
Model | iCooler-4006 | iCooler-4006+ | iCooler-4006P |
Working temperature range (°C) | -40~40 | -40~100 | -40~100 |
Temperature stability (°C) | ±0.3 | ±0.05 | ±0.02 |
Cooling capacity(W) | 800(20℃) | 800(20℃) | 800(20℃) |
Heating capacity (W) | - | 1500 | 1500 |
Pump capacity flow rate (L/min) | 22 | 22 | 22 |
Pump pressure/suction(bar) | 0.3/0.2 | 0.3/0.2 | 0.3/0.2 |
Filling volume(L) | 5 | 4.5 | 6 |