Availability: | |
---|---|
Quantity: | |
Built-in three-level user rights management, audit tracking, test record management, and printing through the device interface
Or USB output test report.
Commonly used sample information management for easy retrieval and use
Commonly used test plans are managed for easy retrieval and use.
High-precision real-time constant temperature control, independent temperature measurement for each dissolution vessel, dual over-temperature protection and temperature calibration functions
able.
There is scheduled heating inside, and the user can set the system to start heating at a specified time.
Manual and automatic synchronized dosing functions.
Manual and automatic sampling dual modes.
Split agitator design, quick replacement.
The dissolution vessel and stirrer are automatically centered.
Sealed anti-evaporation cover design effectively reduces medium evaporation.
Using a more convenient water circulation pipeline design, professional medical grade quick connectors provide IQ/0Q certification documents for free.
Technical Parameters:
Number of high-precision dissolution vessels: 12
Swing range of stirring paddle: ≤0.5 mm
Basket swing range: ≤1.0 mm
Rotation rod and dissolution vessel axis deviation: ≤2.0 mm
Speed setting range: 10~300 RPM
Steady speed error: ≤±1%
Temperature adjustment range: room temperature~45.0℃
Temperature Resolution: 0.1℃
Temperature control accuracy: ≤±0.3℃
Sampling points: ≤100
Sampling timing time: ≤999 hours 59 minutes 59 seconds
Power supply: AC220V±10%, 50Hz
Built-in three-level user rights management, audit tracking, test record management, and printing through the device interface
Or USB output test report.
Commonly used sample information management for easy retrieval and use
Commonly used test plans are managed for easy retrieval and use.
High-precision real-time constant temperature control, independent temperature measurement for each dissolution vessel, dual over-temperature protection and temperature calibration functions
able.
There is scheduled heating inside, and the user can set the system to start heating at a specified time.
Manual and automatic synchronized dosing functions.
Manual and automatic sampling dual modes.
Split agitator design, quick replacement.
The dissolution vessel and stirrer are automatically centered.
Sealed anti-evaporation cover design effectively reduces medium evaporation.
Using a more convenient water circulation pipeline design, professional medical grade quick connectors provide IQ/0Q certification documents for free.
Technical Parameters:
Number of high-precision dissolution vessels: 12
Swing range of stirring paddle: ≤0.5 mm
Basket swing range: ≤1.0 mm
Rotation rod and dissolution vessel axis deviation: ≤2.0 mm
Speed setting range: 10~300 RPM
Steady speed error: ≤±1%
Temperature adjustment range: room temperature~45.0℃
Temperature Resolution: 0.1℃
Temperature control accuracy: ≤±0.3℃
Sampling points: ≤100
Sampling timing time: ≤999 hours 59 minutes 59 seconds
Power supply: AC220V±10%, 50Hz