Availability: | |
---|---|
Quantity: | |
Features:
1. Using international brand compressors, EBM fans and other main components, it has high cooling efficiency, low noise and long service life.
2. The conductive film is attached to the inside of the insulating glass, which generates slight heat and eliminates the problem of condensation in the chromatography cabinet. The vacuum insulation layer formed by two pieces of glass and filled with inert gas can ensure that the internal temperature is not affected by the outside world.
3. Forced air cooling cycle, rapid cooling, and can maintain the constant temperature of the box.
4. The special air duct design makes the temperature evenly distributed, making the cooling effect better. Cooling time: ≤120 minutes.
5. The box body is made of SUS304 high-quality stainless steel, and the corner joints are constructed with arcs.
6. A large and small double-door design. The large door is used for instruments and the small door is used for chromatography columns. It can ensure that collection and chromatography experiments do not interfere with each other and minimize temperature fluctuations.
7. Exquisite space design: multi-layer height-adjustable, push-pull partitions, each partition can withstand more than 30KG, and can easily place other items such as collectors or machine components.
8. There are connection holes in the middle and rear of both sides of the freezer for pipe connections between the chromatograph outside the cabinet - the chromatography column inside the cabinet - the collector inside the cabinet - the detector outside the cabinet. It maintains the low temperature of the chromatography column and the sample, and can perform various chromatography operations conveniently and flexibly.
9. The humanized automatic return door design is more effective in preventing accidental air-conditioning leakage, saving energy and protecting the environment.
10. The new insulation structure of the box door frame reduces the leakage of cold air to the greatest extent and saves energy.
11. The box body adopts integral foaming technology, and the 60mm thick high-density polyester foam insulation layer is integrally foamed and molded to keep the temperature inside the box from external influences.
12. Use advanced LED lighting with higher brightness and no flicker.
13. Caster design, imported brand, easy to move and safe to fix.
14. With UV disinfection function.
15. Antibacterial agent is added to the door seal to achieve antibacterial effect.
16. Comes with dehumidification function.
Technical Parameters:
model | CXG-1300 |
temperature range | 1-10℃ |
Temperature control accuracy | ±(0.5-2)℃ |
Content volume | 1388L |
Internal dimensions | 1320*730*1440mm |
external dimensions | 1440*850*1970mm |
Box material | High quality 304 stainless steel |
Insulation Materials | Overall foam insulation |
Features:
1. Using international brand compressors, EBM fans and other main components, it has high cooling efficiency, low noise and long service life.
2. The conductive film is attached to the inside of the insulating glass, which generates slight heat and eliminates the problem of condensation in the chromatography cabinet. The vacuum insulation layer formed by two pieces of glass and filled with inert gas can ensure that the internal temperature is not affected by the outside world.
3. Forced air cooling cycle, rapid cooling, and can maintain the constant temperature of the box.
4. The special air duct design makes the temperature evenly distributed, making the cooling effect better. Cooling time: ≤120 minutes.
5. The box body is made of SUS304 high-quality stainless steel, and the corner joints are constructed with arcs.
6. A large and small double-door design. The large door is used for instruments and the small door is used for chromatography columns. It can ensure that collection and chromatography experiments do not interfere with each other and minimize temperature fluctuations.
7. Exquisite space design: multi-layer height-adjustable, push-pull partitions, each partition can withstand more than 30KG, and can easily place other items such as collectors or machine components.
8. There are connection holes in the middle and rear of both sides of the freezer for pipe connections between the chromatograph outside the cabinet - the chromatography column inside the cabinet - the collector inside the cabinet - the detector outside the cabinet. It maintains the low temperature of the chromatography column and the sample, and can perform various chromatography operations conveniently and flexibly.
9. The humanized automatic return door design is more effective in preventing accidental air-conditioning leakage, saving energy and protecting the environment.
10. The new insulation structure of the box door frame reduces the leakage of cold air to the greatest extent and saves energy.
11. The box body adopts integral foaming technology, and the 60mm thick high-density polyester foam insulation layer is integrally foamed and molded to keep the temperature inside the box from external influences.
12. Use advanced LED lighting with higher brightness and no flicker.
13. Caster design, imported brand, easy to move and safe to fix.
14. With UV disinfection function.
15. Antibacterial agent is added to the door seal to achieve antibacterial effect.
16. Comes with dehumidification function.
Technical Parameters:
model | CXG-1300 |
temperature range | 1-10℃ |
Temperature control accuracy | ±(0.5-2)℃ |
Content volume | 1388L |
Internal dimensions | 1320*730*1440mm |
external dimensions | 1440*850*1970mm |
Box material | High quality 304 stainless steel |
Insulation Materials | Overall foam insulation |